- A350 Procedures To Reset Fault or Faults
Normal AC Power APU OR EXTERNAL.
FAULT CONDITIONS:AIR REDUNDANCY LOSS ON FUEL INERTING.
SOLUTION:Normal AC Power APU OR EXTERNAL. PERFORM SYSTEM REPORT/21/AGS/TEST/NO BLEED/1/2.>
Dispatch Page:
Circuit breakers or SSPC to reset:INSERTPANEL DESIGNATION CB LOCATION ON A/C ALL CBP1 CPIOM 3209TF 5AC08 ON A/C ALL EPDC2 CPIOM H42 3108TF 4AC07 ON A/C ALL EPDC2 ASCU1 NORM 3106HH 2FC10 ON A/C ALL EPDC1 ASCU2 NORM 3105HH 1FD05 ON A/C ALL EPDC1 ASCU1 EMER 3201HH 1CD06 ON A/C ALL EPDC2 ASCU2 EMER 3202HH 2CD01 ON A/C ALL EPDC1 RAM AIR INLET ACTR 1 3103HH 1KQ01 ON A/C ALL EPDC2 RAM AIR INLET ACTR 2 3104HH 1KP06 ON A/C ALL EPDC1 RAM AIR OUTLET ACTR 1 3107HH 1KG01 ON A/C ALL EPDC2 RAM AIR OUTLET ACTR 2 3108HH 1KE06
OMT SYSTEM REPORT TESTS:Insert Here
Fault Detected By:CSAS
Fault Code:2158H070
Results of power up test or reset:Pass: N/A.
Fail: N/A.
Additional Notes:INSERT.
Manual ReferenceAMM A350.
TSM A350-A-21-53-XX-01001-343A-A.
Applicable deferrals:MEL.
CDL.