- COM OIS/AVIONICS DATA XFR FAULT
• Fault of the AFSC - Avionics Server Function
• Avionics Server Function Cabinet
•COM OIS/AVNCS DATA XFR FAULT Dispatch Message
• Unable to access the Maintenance Menu Backup or Any OIS Menus. All AFSC module LEDs will be flashing amber and not green. All Company COMM is not available.
Procedures to Reset:
• PULL Circuit Breakers in table below.
• Pull C/Bs, remove SMM1 (104TC1) module, close C/Bs & Wait 5-10 minutes.
• After wait, if all AFSC module LEDs don't go green then; pull C/Bs again, install SMM1 module, remove SMM2 (104TC2) module, close C/Bs & wait 5-10 minutes.
• After wait, all AFSC Module LEDs should be green confirming which SMM is bad and dispatch should change to COM OIS/AVNCS REDUNDANCY. C/W MEL, for Dispatch.
• SMM1 (104TC1) or SMM2 (104TC2).
Circuit breakers or SSPC to reset:PANEL DESIGNATION CB LOCATION ON A/C ALL EPDC1 3103TC 1FD03 ON A/C ALL EPDC1 3109TC 1JB04 ON A/C ALL EPDC1 3201TC 1CA02 ON A/C ALL EPDC1 3203TC 3HC05
OMT SYSTEM REPORT TESTS:ATA 46.
Fault Detected By:FWS_OIS/AFSC
Results of power up test or reset:Pass: DISPATCH MESSAGE fault disappears.
Fail: DISPATCH MESSAGE fault remains.
Additional Notes:RESET ALL CB'S AGAIN IF NO HELP.
Description Of Fault:AFSC/OIS Cabinet Falls to Boot.
FAULT CODES:4611NXXX
Manual ReferenceAMM .
AMM .
FIM TSM A350-A-46-12-01-3D002-421A-A.
Applicable deferrals:MEL
CDL.