- AIR ENG 1 OR 2 BLEED TEMP REDUNDANCY
CLOSE ALL CB'S PERFORM THE SYSTEM REPORT AND TEST ATA 36 BLEED 1 OR 2.
Circuit breakers or SSPC to reset:PANEL DESIGNATION CB LOCATION ON A/C ALL CBP2 BOMU2 BAM CARD 3200HA 6AJ05 ON A/C ALL CBP1 BOMU1 BAM CARD 3201HA 5AH14 ON A/C ALL CBP2 BOMU2 BAM OHDU CARD 3202HA 6AD14 ON A/C ALL CBP1 BOMU1 BAM OHDU CARD 3202HA 5AG01 ON A/C ALL EPDC1 CPIOM H43 3103TF 1KR05 ON A/C ALL EPDC1 CPIOM H44 3110TF 2KL02 ON A/C ALL EPDC1 CRDC B05 3121TS 1KH04 ON A/C ALL EPDC1 CRDC B05 DSO GP3 3145TS 1KF05 AC 3501-3205,3571 EPDC1 CRDC B05 DSO GP2 3143TS SSPC ON A/C ALL EPDC2 CRDC B02 3114TS 2KG02 ON A/C ALL EPDC2 CRDC B02 DSO GP1 3134TS 2KJ03 ON A/C ALL EPDC2 CRDC B02 DSO GP3 3138TS 2KJ02 ON A/C ALL EPDC1 ASCU2 NORM 3105HH 1FD05 ON A/C ALL EPDC2 ASCU1 NORM 3106HH 2FC10 ON A/C ALL EPDC2 ASCU1 EMER 3201HH 1CD06 ON A/C ALL EPDC2 ASCU2 EMER 3202HH 2CD01 ON A/C ALL CBP1 CRDC A01 3201TS 5AB15 ON A/C ALL CBP2 CRDC A02 3202TS 6AE03 ON A/C ALL EPDC1 CRDC A01 BKUP 3153TS 3AD06 ON A/C ALL EPDC2 CRDC A02 BKUP 3102TS 2KN04
OMT SYSTEM REPORT TESTS:ATA 36.
Fault Detected By:EBAS
Results of power up test or reset:Pass: DISPATCH MESSAGE fault disappears.
Fail: DISPATCH MESSAGE fault remains.
Additional Notes:RESET ALL CB'S IF NO HELP.
Description Of Fault:Redundancy.
FAULT CODES:3621HXX
Manual ReferenceAMM A350-A-36-12-XX-01001-398A-A.
AMM A350-A-XXXXXXXXXXXXXXX.
FIM.
Applicable deferrals:MEL
CDL.